Heavy-duty aluminum alloy or wooden tripod; stable and non-slip; suitable for setup in all working conditions.
Product Overview
The DSZ series precision automatic level is a high-precision professional optical surveying instrument widely used in scenarios requiring precise elevation measurements, such as building construction, municipal engineering, road and bridge projects, hydraulic dam construction, and foundation pit settlement monitoring. Equipped with a suspension-wire magnetic damping automatic compensation system, the device offers stable compensation and strong interference resistance. Both DSZ2 and DSZ3 adopt IP67 dustproof and waterproof rating, designed to withstand challenging outdoor conditions, including rain, dust, and temperature extremes. Featuring high measurement accuracy, stable performance, and ease of use, it serves as a core instrument for engineering elevation control, building settlement observation, and precision leveling.
Working Principle: Automatic Leveling
The DSZ series automatic level adopts optical levelling principles to build a high-precision horizontal line of sight. It comes with a built-in suspension-wire magnetic damping compensator, which can automatically correct slight tilts and remove manual fine-levelling work. DSZ2 and DSZ3 are equipped with this compensation structure. After simple rough levelling with the circular bubble, the compensator automatically adjusts the optical path and keeps the telescope line of sight horizontal. Operators read data on the levelling staff, and the instrument can accurately calculate the elevation difference between two points. It supports fast elevation measurement, elevation checking and building settlement monitoring for construction projects.
Installation and Usage Steps
Setup and Rough Levelling: Mount the DSZ series automatic level on a professional tripod. Adjust the levelling screws to centre the circular bubble to finish rough levelling. Thanks to the built-in suspension-wire magnetic damping compensator, manual fine levelling is not required.
Aiming and Focusing: Rotate the telescope to aim at the levelling staff. Use the dual-speed focusing knob for fast coarse focusing and precise fine focusing; eliminate parallax to obtain a sharp, bright erect image.
Precise Reading: Read the scale value on the levelling staff with the centre horizontal crosshair and stadia hairs, and manually record the measurement data.
Re-measurement and Verification: Carry out round-trip observations at multiple stations to cross-check data and reduce measurement errors, guaranteeing accurate and reliable survey results.
Technical Specifications
|
Parameter Name |
Parameter Value |
|
Model |
DSZ2 |
|
Magnification |
42X |
|
Objective Aperture |
45mm |
|
Precision (Double-run per km) |
1.0mm |
|
Compensation Method |
Suspension-wire Magnetic Damping |
|
Compensation Range |
±15′ |
|
Minimum Sighting Distance |
0.6m |
|
Image Orientation |
Erect |
|
Waterproof Rating |
IP67 |
|
Operating Temperature |
-20°C~+50°C |
|
Standard Accessories |
Main instrument, carrying case, adjusting pin |
|
Parameter Name |
Parameter Value |
|
Model |
DSZ3 |
|
Magnification |
38X |
|
Objective Aperture |
45mm |
|
Precision (Double-run per km) |
1.5mm |
|
Compensation Method |
Suspension-wire Magnetic Damping |
|
Compensation Range |
±15′ |
|
Minimum Sighting Distance |
0.6m |
|
Image Orientation |
Erect |
|
Waterproof Rating |
IP67 |
|
Operating Temperature |
-20°C~+50°C |
|
Standard Accessories |
Main instrument, carrying case, adjusting pin |
Applications
Monitoring Overview
The DSZ2 and DSZ3 meet high measurement standards and are suitable for precision elevation measurement and long-term settlement monitoring across various engineering projects. Stable, durable, and highly resistant to environmental interference, they are essential precision instruments for civil construction, municipal renovation, bridge, hydraulic and foundation pit monitoring. They do not support electronic data collection; manual reading and recording are required.
Compatible Accessories
01
Surveying Tripod
Heavy-duty aluminum alloy or wooden tripod; stable and non-slip; suitable for setup in all working conditions.
02
Leveling Staff
3m/5m telescopic staff; wear-resistant graduations; clear and accurate readings.
03
Staff Plate
Sturdy steel plate; designed for soft ground to prevent settlement errors.
04
Precision Micrometer
Used to upgrade measurement precision to 0.5mm.
05
Protective Case
Shock-resistant and crush-proof; portable storage; protects the instrument during long-distance transport.
06
Adjustment Tools
Dedicated adjustment wrench and pin; for routine precision adjustment and maintenance.
Calibration and Maintenance
It is recommended to calibrate the instrument every 12 months; recalibration is mandatory following drops, impacts, or prolonged storage.
Circular Level Calibration
Adjust the leveling screws to center the bubble precisely, ensuring no offset or parallax.
i-Angle Accuracy Check
Compare readings over a standard distance to correct the instrument's systematic error.
Lens Maintenance
Clean using a dedicated lens cloth; do not rinse with water or use chemical solvents.
Storage and Care
For long-term storage, include a desiccant and keep the instrument in a dry, well-ventilated environment to prevent moisture and mold.
WE LOOK FORWARD TO WORKING WITH YOU.
We have been committed to providing high-precision measurement equipment and reliable measurement solutions for global construction, engineering, surveying, and land surveying projects.