Standard heavy-duty survey tripod for stable instrument setup.
Product Overview
The Qiantu QZJ2‑2 is a dust‑proof and water‑proof portable laser plumb instrument. It generates upward and downward coaxial laser beams that are concentric and confocal with the telescope collimation axis. Equipped with a filter‑enhanced visible eyepiece, operators can safely observe the upper laser spot without harm to human eyes. Its vertical axis adopts advanced retainer‑frame structure to deliver superior rotation accuracy and stability. The downward laser plummet is built‑into the vertical axis and requires no manual calibration for high‑efficiency field work. With full‑unit dust‑proof and water‑proof construction, it resists moisture caused by rain and splashes on construction sites. It supports both rechargeable lithium battery and dry battery power supply. This instrument serves as reliable vertical reference baseline for high‑rise buildings, elevator shafts, mine shafts, water towers, chimneys, large tower frames and heavy‑duty equipment installation, widely used in building construction, engineering installation and project supervision.
Working Principle
The Qiantu QZJ2‑2 laser plumb instrument projects two coaxial upper‑and‑lower laser beams perfectly aligned with the telescope sight axis. After being mounted on tripod and well‑levelled, the downward laser marks the ground benchmark point, meanwhile the upward laser projects vertically to upper floors. Thanks to the filter‑fitted visible eyepiece, users can view upper laser spot clearly. Precision‑machined retainer‑frame vertical axis guarantees stable rotation performance, to complete accurate vertical point transfer between ground and multi‑level floors for vertical alignment tasks. There is no built‑in automatic compensator; its stability relies on high‑precision mechanical vertical‑axis structure.
Operation Guide
Set Up: Secure the Qiantu QZJ2‑2 laser plumb instrument onto a stable tripod, level the instrument by adjusting foot screws according to the circular bubble.
Align: Fine‑tune instrument position until the downward laser spot overlaps the ground benchmark point.
Read: Watch the upward laser spot projected on upper‑floor target plate and record vertical offset data.
Move & Repeat: Reposition instrument to other measuring stations and repeat above steps for multi‑point vertical inspection.
Technical Specifications
|
Parameter Name |
Content |
|
Model |
QZJ2‑2 |
| Upward Plumb Standard Deviation | 1/10000 |
| Down‑pointing Limit Deviation | 1/2000 |
| Long Level Vial Sensitivity | 30" /2mm |
| Telescope Magnification | 28x |
| Laser Wavelength | 635nm |
| Laser Output Power | 1mW |
| Laser Spot Diameter | 3mm@50m |
| Coaxial Error between laser axis & collimation axis |
5" |
| Laser Working Range | ≥200m(daytime), ≥250m(night) |
| Power Supply | Rechargeable lithium battery / Dry battery |
| Continuous Working Time |
8 hours |
| Operating Temperature | ‑10℃ ~ +45℃ |
| Dimension | 130 × 300 mm |
| Weight | 3.3 kg |
Applications
Note on Deformation Monitoring
As a laser plumb instrument for vertical point transfer, the IXJ2-5 is not designed for high-precision continuous deformation monitoring over long distances. It is mainly used for on-site vertical alignment and vertical point transmission.
Compatible Accessories
01
Tripod (aluminum or wood)
Standard heavy-duty survey tripod for stable instrument setup.
02
Laser Target Plate
Reflective target plate to clearly show laser spot in bright daylight.
03
Brass Foot Screws
Precision adjustment foot screws for fine leveling.
04
Instrument Hard Case
Shockproof hard carrying case for storage and transport protection.
05
Rechargeable Lithium Battery Spare
Backup battery for long-time site field operation.
06
Sunshade
Reduce strong sunlight interference to improve laser visibility outdoors.
Calibration & Maintenance
Regular calibration ensures continued accuracy of the IXJ2-5. Recommended calibration interval is 12 months or after any heavy impact or long-term storage.
Circular Vial Calibration
Adjust foot screws until the air bubble is centered without parallax.
Laser Verticality Accuracy Check
Place the instrument on stable ground, project laser upward to a target plate, rotate instrument 360°, check laser point offset to verify vertical accuracy.
Lens Protection
Keep the laser window clean. Use soft lens cloth to wipe dust, avoid harsh chemicals on optical surfaces.
Cleaning
Wipe the housing with dry soft cloth. Do not rinse the instrument directly with water.